Hands-On Experiments Possible
Using this system, students and instructors can perform the
following activities:
- Observation
of Current Waveform for Linear & Nonlinear Loads and Calculations
- Impact
of Transmission Line Inductance on Voltage Quality at PCC
- Power
factor improvement using capacitor bank and its impact on power quality at
PCC
- Grid
Synchronization of Solar PV Inverter and its Performance Analysis
- Evaluation
of Active, Reactive & Apparent power Flow between Grid-Tied Inverter,
Grid &Load and Net Metering concept
- Demonstration
of Anti-Islanding protection of Grid-Tied Inverter for Sudden Grid Failure
and running the system using virtual grid
Installation & Training at SMVDU
Following the successful delivery and installation of the
Solar PV Grid-Tied Training System at SMVDU, Ecosense conducted a 1-day
Master’s Training Program. This training was provided to faculty members,
lab staff, and research assistants to ensure smooth operational understanding
of the system and efficient curriculum integration.
The training included:
- System
overview and theoretical background.
- Inverter
operations and virtual grid functions.
- Live
demonstration of solar energy generation and grid tie-in.
- Electrical
safety and component protection.
- Experiment
walkthroughs for teaching staff.
Faculty appreciated the intuitive layout and industrial
relevance of the system, expressing enthusiasm for its use in upcoming lab
courses and practical sessions.